Duct Damper standards

Product NameDuct Damper standards
MaterialPlastic,ABS,PVC or other material
ColorWhite or custom color
StandardChina standard
SizeCustomized
MOQ10
PackagingStandard packaging
Delivery30day
  • HVAC Duct Systems Inspection Guide | SMACNA

    The Fire, Smoke and Radiation Damper Guide (5th edition) also summarizes installation details. Checklists are included for ductwork and fire dampers. Valuable as a study guide for the HVAC Duct Construction Standards manual and for learning inspection procedures in general. Includes soft metrics.

    Ask For Quote Details
  • Fire safety

    Fire dampers, which are usually installed in ventilation ducts to prevent fire spread, are not permitted within a kitchen exhaust duct system. They do not work in kitchen exhaust because grease on the downstream side of the damper will ignite before, and irrespective of, damper closure. The potential for false operation of the fire damper

    Ask For Quote Details
  • Chapter 6: Duct Systems, Mechanical Code 2015 of

    Only fire dampers and ceiling radiation dampers labeled for use in dynamic systems shall be installed in heating, ventilating and air-conditioning systems designed to operate with fans on during a fire. Smoke dampers shall comply with the requirements of UL 555S. Combination fire/smoke dampers shall comply with the requirements of both UL 555

    Ask For Quote Details
  • Manhattan 2 Fan and Damper Interconnection

    features on internal duct wall can withstand significantly greater load forces than typical grillemounting hardware. 1.4.3 Researchers Propose Standards that Support Replacing Grille with Motorized Damper In theory, one can replace a grille with a motorized fan and/or damper, and make use of existing mounting hardware (e.g. two

    Ask For Quote Details
  • Pressure Balancing Supply and Return Ducts in Existing

    Ideally, each supply branch duct should already have a manual balancing damper, typically located at the supply trunk take-off, to adjust airflow to each room. If so, incrementally adjust the dampers to reduce airflow to the comfortable rooms and thereby increase airflow to the uncomfortable room(s).

    Ask For Quote Details
  • SMACNA CAD STANDARD

    SMACNA CAD Standard Second Edition v NOTICE TO USERS OF THIS PUBLICATION 1. DISCLAIMER OF WARRANTIES a) The Sheet Metal and Air Conditioning Contractor's National Association (“SMACNA”) provides its product for informational

    Ask For Quote Details
  • UL APPROVED BREAKAWAY DUCT CONNECTIONS

    SMACNA Duct Constructions Standards. Standard 6” (152 mm) metal clip may be used with spacing as shown in Figure 4. Three-eighths inch (10mm) metal bolts and .Damper Sleeve or Duct Add-on duct connection Butyl or Neoprene Gasket Damper Sleeve or Duct Fasten per manufacturer instruction #10 x ¾” (19) Tek Screw Add-on duct

    Ask For Quote Details
  • Duct Splitter Dampers | Products & Suppliers | Engineering360

    New York Blower Company (The) Duct Fan New York Blower Duct Fans are designed and constructed for low pressure ventilating and industrial exhaust applications requiring the compactness of an axial fan. In applications where equipment space is at a premium, the compact flow-through design of the Duct Fan can reduce system space requirements by more than 50% over conventional centrifugal fans.

    Ask For Quote Details
  • 2012 IBC

    Exception: A duct is permitted to penetrate three floors or less without a fire damper at each floor provided it meets all of the following requirements. 1. The duct shall be contained and located within the cavity of a wall and shall be constructed of steel having a minimum thickness of 0.0187 inch (0.4712 mm) (No. 26 gage). 2.

    Ask For Quote Details
  • UL 710

    Exhaust hoods with fire actuated fire exhaust dampers are intended to have the exhaust fire actuated dampers automatically close to prevent exhaust duct gas temperatures from exceeding 375°F (191°C). All exhaust hoods are intended for use with fire extinguishing system units.

    Ask For Quote Details
  • 23 31 00 HVAC DUCTS AND CASINGS

    Every runout duct shall be provided with a low-loss rectangular 45° tap or round bell-mouth tap from the main duct. A manual balancing damper shall be installed at the take-off and used for balancing rather than relying on damper at air distribution devices in the space. Comply with SMACNA's "HVAC Duct Construction Standards - Metal and

    Ask For Quote Details
  • UFGS 23 31 13.00 40 Metal Ducts

    2.2.6 Dampers 2.2.7 Sound Traps 2.2.7.1 Attenuation 2.2.7.2 Construction of Sound Traps 2.2.8 Flexible Connectors for Sheet Metal 2.2.9 Duct Hangers 2.2.10 Mill-Rolled Reinforcing and Supporting Materials 2.2.11 Flexible Duct Materials 2.2.12 Manual Volume Dampers 2.2.12.1 Damper Construction 2.2.13 Gravity Backdraft and Relief Dampers

    Ask For Quote Details
  • UL APPROVED BREAKAWAY DUCT CONNECTIONS

    SMACNA Duct Constructions Standards. Standard 6” (152 mm) metal clip may be used with spacing as shown in Figure 4. Three-eighths inch (10mm) metal bolts and .Damper Sleeve or Duct Add-on duct connection Butyl or Neoprene Gasket Damper Sleeve or Duct Fasten per manufacturer instruction #10 x ¾” (19) Tek Screw Add-on duct

    Ask For Quote Details
  • Technical Resources

    The revised “Round Industrial Duct Construction Standards,” 3rd edition, 2013, an American National Standard, ANSI/SMACNA 005-2013, is now available.Session highlights the considerations in specifying and installing fire dampers, smoke dampers, combination fire and smoke dampers and ceiling dampers in HVAC systems.

    Ask For Quote Details
  • IR8

    to meet low-lead standards. Please check the box below to confirm you are aware that thisDampers do not close completely Specs Duct Size: Material: Galvanized Steel Type:

    Ask For Quote Details
  • Fume Exhaust Duct Catalog

    STANDARDS DUCT & FITTINGS CONTROL DEVICES 4" - 12" Wafer Isolation Damper 24 PSP-EZ™ Clamp Mechanical Specifications 8 Straight Duct with Lateral Tap 15 46 44 42 9 23 2" & 3" Micro-Adjustable EZ Damper 25 6" - 14" AMCA Industrial Isolation Damper 29 Custom Fitting 22 Concentric Round to Rectangular Transition 21 6" - 14" Industrial Isolation

    Ask For Quote Details
  • MAINTENANCE AND TESTING OF FIRE/SMOKE DAMPERS

    protected by smoke dampers be maintained in accordance with NFPA 105(2010). MSFC(15), Sec. 703.1.3 requires that openings protected by fire dampers be maintained in accordance with NFPA 80(2010). Applicable standards NFPA 101(12), Sec. 9.2.1 requires that air conditioning, heating, ventilating ductwork and related equipment be

    Ask For Quote Details
  • A GUIDE TO INSULATED HVAC DUCT SYSTEMS

    Duct board products are available with coated or faced airstream surfaces. These products permit rigorous cleaning of the duct surface where dust has been allowed to collect in the duct due to lack of filtration or poor maintenance. Additionally, some of these products have higher maximum velocity ratings.

    Ask For Quote Details
  • Back

    SCOPE . If exhaust fans share a common duct, verify that each fan has its own damper; install if missing. See the Scope tab for additional job specifications.. If the project will involve working in the attic, see the assessment guide, Pre-Retrofit Assessment of Attics, Ceilings, and Roofs. For more on supply ventilation, see the U.S. Department of Energy's Standard Work Specifications on e

    Ask For Quote Details
  • (PDF) FIRE, SMOKE AND RADIATION DAMPER INSTALLATION

    FIRE, SMOKE AND RADIATION DAMPER INSTALLATION GUIDE FOR HVAC SYSTEMS SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, INC. Download.Design and Construction Standards Division 23 – Heating, Ventilating and Air Conditioning (HVAC. By Taha Mech.

    Ask For Quote Details
  • TECHNICAL MANUAL

    Method 4 Protection using Fire and Smoke Dampers (automatically actuated via smoke detectors) There are a number of Standards related to the testing of products suitable for use as fire resisting duct systems as follows: British Standards BS 476 Pt24:1987 Method for the determination of the fire resistance of ventilation ducts European Standards

    Ask For Quote Details


Our Location

Contact Us

Boda Aluminum Products Co.,LTD

Address: Jingjiang, Taizhou City
Jiangsu Province, China
Zip code - 214500
Telephone: +86 18262317598
E-mail: [email protected]