Available Duct Damper standards

Product NameAvailable Duct Damper standards
MaterialPlastic,ABS,PVC or other material
ColorWhite or custom color
StandardChina standard
SizeCustomized
MOQ10
PackagingStandard packaging
Delivery30day
  • TECHNICAL MANUAL

    Method 4 Protection using Fire and Smoke Dampers (automatically actuated via smoke detectors) There are a number of Standards related to the testing of products suitable for use as fire resisting duct systems as follows: British Standards BS 476 Pt24:1987 Method for the determination of the fire resistance of ventilation ducts European Standards

    Ask For Quote Details
  • Guidelines for Seismic Verification of HVAC Duct and

    attached to HVAC ducts are also included. The guidelines apply to duct fabricated of hot-rolled and cold-rolled carbon steel, galvanized sheet steel, stainless steel and aluminum in accordance with SMACNA standards [5]. The guidelines are applicable to any HVAC duct and damper system at any elevation in a plant where the nuclear

    Ask For Quote Details
  • Examination of the fire resistance requirements for ducts

    A comparison of the different test methods available for assessing the performance of ducts and dampers, including the new European approach was carried out.3.1.2 Technical Standards, Scotland 3 3.1.3 Technical Booklet E (Northern Ireland) 3duct/damper is installed in.

    Ask For Quote Details
  • Fire and Smoke Damper Maintenance

    The maintenance of Fire and Smoke dampers is documented in AS1851, Section 18. Within this standard it also touches on other applicable standards. AS3666.1 - 4 (Air-Handling and water systems of building – Microbial Control) AS1668.1 + 2 (The use of ventilation and air conditioning in buildings) AS1682.2 (Fire damper Installation)

    Ask For Quote Details
  • ANSI/SMACNA 006

    Information Required for Duct Construction 8. Location and types of any fire protection device including fire dampers, smoke dampers, combination fire/smoke dampers, and ceiling dampers. Building codes require this information to be shown on the design documents submitted for building permit.

    Ask For Quote Details
  • Back

    SCOPE . If exhaust fans share a common duct, verify that each fan has its own damper; install if missing. See the Scope tab for additional job specifications.. If the project will involve working in the attic, see the assessment guide, Pre-Retrofit Assessment of Attics, Ceilings, and Roofs. For more on supply ventilation, see the U.S. Department of Energy's Standard Work Specifications on e

    Ask For Quote Details
  • Smoke & Fire Damper Testing | Pro

    This code of practice also includes BS 9999, which states that fire dampers should be cleaned and maintained at intervals stated below. Fire dampers are crucial passive fire protection products used in heating, ventilation, and air conditioning ducts to prevent the spread of fire inside the ductwork through fire-resistance rated walls and floors.

    Ask For Quote Details
  • Installation Instructions Slip

    CAUTION: Never force dampers into an undersized duct system, the excess pressure can cause damper blades to jam and cause improper operation. NOTE: All dampers must be properly installed and supported according to local codes or SMACNA standards. Seal duct joints using duct tape, mastic, or other approved methods.

    Ask For Quote Details
  • Manhattan 2 Fan and Damper Interconnection

    features on internal duct wall can withstand significantly greater load forces than typical grillemounting hardware. 1.4.3 Researchers Propose Standards that Support Replacing Grille with Motorized Damper In theory, one can replace a grille with a motorized fan and/or damper, and make use of existing mounting hardware (e.g. two

    Ask For Quote Details
  • Key Item Check Questions to Ask D® American National

    Why are duct design calculations important? Achieving occupant satisfaction is the principal goal of any HVAC design. For residential air duct designs ACCA's Manual D is the procedure recognized by the American National Standards Institute (ANSI) and spe-cifically required by residential building codes. Air is the first word in air conditioning.

    Ask For Quote Details
  • SMACNA CAD STANDARD

    SMACNA CAD Standard Second Edition v NOTICE TO USERS OF THIS PUBLICATION 1. DISCLAIMER OF WARRANTIES a) The Sheet Metal and Air Conditioning Contractor's National Association (“SMACNA”) provides its product for informational

    Ask For Quote Details
  • Effect of Inlet Duct and Damper Design on Fan Performance

    Effect of Inlet Duct and Damper Design on Fan Performance and Static Pressure Measurements (ASHRAE RP 1743)This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries.the AHRI and ASHRAE testing standards that reduces the risk of false testing failures and will lead higher integrity

    Ask For Quote Details
  • Ductwork

    Duct construction as per DW144 / SMACNA / ASHRAE standards provides superior strength, low leakage rate and vibration free products Spiral duct diameter varies from min of 125mm to max of 3000mm Individual pipe lengths available upon request and also available in aluminum and stainless steel

    Ask For Quote Details
  • Fire and Smoke damper standards

    Overview of standards Background Changes to AS1682 and referenced standards General Changes Installation Overview General requirements Product testing Fire dampers Smoke dampers Summary. Watch the timer!!!! AUS Building Code NBCC AS 1668.1 (2015) AS 1682.1 & 1682.2Duct Joints. Break-away Joint. retaining flanges Oversize hole

    Ask For Quote Details
  • Air Balancing 101

    Basics. “Dampers” are used to balance airflows, and there are three types: 1. “Volume dampers” provided in the branch ducts, typically at the connections to. the main ducts. 2. “Opposed blade dampers” integral with air outlets; this type is characterized by. pairs of damper blades that move in opposite directions. 3.

    Ask For Quote Details
  • NFPA Standards: Building Code Standard: Standard Construction

    Class 1 Smoke Damper with 3V Blades Actuator Requirements: UL555S requires that all leakage rated dampers be provided with factory mounted actuators. Available actuators vary by damper size and velocity, pressure and temperature ratings. Consult UL Damper Actuator Reference Chart for current offering.

    Ask For Quote Details
  • AMCA certification

    Dampers(Round) "VI-A-TROL" Low Leakage Control Damper: Unapproved catalog made available to the public. Catalog published without the Certified Ratings Program review. 30 October 2019: Humongous Fan Large Diameter Ceiling Fan HVLS Fans Falsely stating that AMCA does not certify CFM ratings for fans larger than 8' in diameter. 11 January 2019

    Ask For Quote Details
  • FDB2 A0(A60) Fire and gas damper for marine applications

    FDB2 fire dampers meet international standards for both rectangular (width B 100-1200 mm and height H 100-1600 mm, 1 mm division) and circular ducts (Ø100-1250 mm). Modular constructions are available for bigger sizes. Non-standard dimensions and flange drilling available on request.

    Ask For Quote Details
  • Isolation Dampers

    These dampers are available in round, square, and rectangular shaped housings, making them adaptable to most applications. Our round isolation damper is designed for sealing off and/or controlling airflow in round ducts and pipes. The square isolation damper is designed for use as a single damper in ductwork.

    Ask For Quote Details
  • 12VDC Damper Actuator | Products & Suppliers | Engineering360

    Actuator models available for various shaft sizes that allow damper shaft to operate centered inside the output … • Models available with 0 to 10 Vdc , 2 to 10 Vdc, and 4 to 20 mA … Mitigation of seismic responses on building structures using MR dampers with Lyapunov‐based control

    Ask For Quote Details
  • Dampers

    • Automatic electrical, pneumatic or spring operation system available. • Maximum duct pressure: 5000 Pa. Maximum air velocity: 15 m/s. dimensions and material thickness The dampers meet international standards for rectangular (width B 100-1200 mm and height H 100-1600 mm, 1 mm division) and circular ducts (Ø 100-1250 mm). Modular

    Ask For Quote Details


Our Location

Contact Us

Boda Aluminum Products Co.,LTD

Address: Jingjiang, Taizhou City
Jiangsu Province, China
Zip code - 214500
Telephone: +86 18262317598
E-mail: [email protected]